Mounting

1776 001-002 / 1776 073-074:
Adjustable bracket, stainless steel 316, unpainted with 5 holes, Ø 10.5 / 14 mm

1776 060-066 / 1776 005-028:
2 adjustable brackets, stainless steel 316, unpainted with 2 mounting holes each, Ø 14 mm

Electric

1776 001-002 / 1776 073-074:
Flexible wiring, silicone insulated, heat resistant up to 180° C, exterior connection box; terminal 3 - pole / 6 mm².

1776 060-066:
Flexible wiring, silicone insulated, heat resistant up to 180° C, 2 exterior connection boxes with 1 ignition unit each; terminal 3 - pole / 6 mm².

1776 005-028:
Flexible wiring, silicone insulated, heat resistant up to 180° C, exterior connection box with ignition unit, ballast incorporated; terminal 3 - pole / 6 mm².

Housing

Housing made of stainless steel AISI316 deep drawn and powder coated white RAL 9016.
Special colours available on request.

Lightsource/Optic

The floodlight is available for different light sources with E40 lamp holder:

1776 001-002: 
(Not included.) High pressure sodium lamps (HS ) / metal halide lamps (HI). 

1776 073-074: 
(not included) Halogen lamp 500W 

1776 060-066: 
(Not included.) High pressure sodium lamps (HS ) / metal halide lamps (HI)

1776 005-028:
(Not included.) High pressure sodium lamps (HS ) / metal halide lamps (HI)


Aluminium reflector in Wide (WB) or Narrow beam (NB) covered by a safty glass pane gives a high light output.

Remarks

Ballast unit has to be ordered separatly for floodlights without incorporated ballast. See type no 1527. Use lamps from well known manufactures only.

Application

Hazardous areas zone 2

Design

According to international rules for zone 2 and EN 50021:1999 / IEC 79-15, EN 60079-15:2005

Ambient Temperature

- 20° C up to + 55° C

Finish

Powder coated white RAL 9016 and enamelled up to 70 - 80 μm thickness.

Pane

Safety glass

Cable entry

Brass cable gland M 24 x 1.5 MGCG; standard for cable dia. 10 to 12.5 mm.