Close
(0) items
You have no items in your shopping cart.
All Categories
    Filters
    Preferences
    Search
    Manufacturer: Drager

    Drager PAC 7000

    Call for pricing
    SKU: JG_1178

    Request availability and price for this product

    Please request availability and pricing for this product by clicking the "Create Ticket" button.

     

    Safety at the workplace always takes priority: depending on the sensor selection, the single gas detector, Dräger Pac 7000, provides a reliable warning against dangerous concentrations of 14 different gases. Unique: the optional 5-year warranty for the H2S, O2 and CO versions.
    Product benefits
    Warns against hazardous gas concentrations

    Every working day places the highest demands on gas monitoring. The device reliably warns against hazardous concentrations of carbon monoxide, hydrogen sulphide (including a Low Concentration option), oxygen, carbon dioxide, sulphur dioxide, chlorine, hydrogen cyanide, ammonia, nitrogen dioxide, nitrogen monoxide, phosphine and organic vapours.
    Robust and long-lasting
    Protective rubber ensures that the casing of the Dräger Pac 7000 is particularly shock-proof. The device meets the strict dust and water protection requirements specified in IP 66/67. The electromagnetic resistance has also been optimised. Dräger has designed the Dräger Pac 7000 for unlimited lifetime. When needed, the sensors can be simply replaced.
    Simple calibration and configuration
    The bump test mode and sensitivity calibration can be selected via a password-protected menu. The fresh air calibration can be optimally protected using a password. The device is equipped with an infrared interface and can be connected to a PC via a communication cradle or the Dräger E-Cal system, in order to activate the desired functions or download stored data.
    Fast bump tests with the Dräger Bump Test Station
    To perform an automatic function test with a known gas concentration within a matter of seconds, the device is simply inserted into the Dräger Bump Test Station. The display informs the user if the bump test (function test) was successful. If the test is not performed within a certain time frame, the device can be set-up to deactivate itself.
    Innovative miniature sensors
    The innovative Dräger XXS sensors react quickly and produce reliable measurement results. Very short diffusion paths inside the device, as well as the sensors' rapid electrochemical reactions, ensure that any gas-related dangers are displayed as soon as they occur. For maximum safety, the sensor is positioned inside the housing such as to allow gas to reach it from above and from the front. This guarantees flawless measurement, even when the gas entry has been accidentally obstructed.
    Triple alarm for extra safety
    As soon as the adjustable alarm thresholds are exceeded, or values fall below the configured oxygen concentration, the Dräger Pac 7000 immediately issues an audible, visual and vibrating alarm. In addition, the device is also equipped with adjustable TWA and STEL alarms. The user is also warned when the battery is low or a functional error has occurred.
    5-year guarantee option
    Dräger offers an optional 5-year warranty for the hydrogen sulphide, oxygen and carbon monoxide monitors..



    Brochure
    Safety at the workplace always takes priority: depending on the sensor selection, the single gas detector, Dräger Pac 7000, provides a reliable warning against dangerous concentrations of 14 different gases. Unique: the optional 5-year warranty for the H2S, O2 and CO versions.
    Product benefits
    Warns against hazardous gas concentrations

    Every working day places the highest demands on gas monitoring. The device reliably warns against hazardous concentrations of carbon monoxide, hydrogen sulphide (including a Low Concentration option), oxygen, carbon dioxide, sulphur dioxide, chlorine, hydrogen cyanide, ammonia, nitrogen dioxide, nitrogen monoxide, phosphine and organic vapours.
    Robust and long-lasting
    Protective rubber ensures that the casing of the Dräger Pac 7000 is particularly shock-proof. The device meets the strict dust and water protection requirements specified in IP 66/67. The electromagnetic resistance has also been optimised. Dräger has designed the Dräger Pac 7000 for unlimited lifetime. When needed, the sensors can be simply replaced.
    Simple calibration and configuration
    The bump test mode and sensitivity calibration can be selected via a password-protected menu. The fresh air calibration can be optimally protected using a password. The device is equipped with an infrared interface and can be connected to a PC via a communication cradle or the Dräger E-Cal system, in order to activate the desired functions or download stored data.
    Fast bump tests with the Dräger Bump Test Station
    To perform an automatic function test with a known gas concentration within a matter of seconds, the device is simply inserted into the Dräger Bump Test Station. The display informs the user if the bump test (function test) was successful. If the test is not performed within a certain time frame, the device can be set-up to deactivate itself.
    Innovative miniature sensors
    The innovative Dräger XXS sensors react quickly and produce reliable measurement results. Very short diffusion paths inside the device, as well as the sensors' rapid electrochemical reactions, ensure that any gas-related dangers are displayed as soon as they occur. For maximum safety, the sensor is positioned inside the housing such as to allow gas to reach it from above and from the front. This guarantees flawless measurement, even when the gas entry has been accidentally obstructed.
    Triple alarm for extra safety
    As soon as the adjustable alarm thresholds are exceeded, or values fall below the configured oxygen concentration, the Dräger Pac 7000 immediately issues an audible, visual and vibrating alarm. In addition, the device is also equipped with adjustable TWA and STEL alarms. The user is also warned when the battery is low or a functional error has occurred.
    5-year guarantee option
    Dräger offers an optional 5-year warranty for the hydrogen sulphide, oxygen and carbon monoxide monitors..



    Brochure

    This site uses cookies to securely store information on your computer.
    These cookies are designed to optimize your browsing experience on this site.
    Note: By logging into the Restricted Area of this website, you are automatically accepting that cookies are stored on your computer as they are indispensable for login action.

    Learn more